Skip to content

Guarisco Phoenix Blu Top 18L/24L LED - Autoclave with Osmosis System

€2.945,00 (Incl. VAT)
In stock
Size

Notify me when back in stock

✅ Free shipping within the EU
✅ Easy returns
✅ Price match guaranteed

Phoenix Blu Top 18L/24L LED Autoclave with Osmosis System + Free Water Distiller

This is a Class B autoclave available in 18 liter and 24 liter capacity, designed for dental clinics, medical practices, veterinary use, and beauty centers.

This steam steriliser provides reliable sterilisation of dental instruments, surgical tools, and hollow or porous instruments. It includes a built in top mounted osmosis system with automatic water purification, automatic water filling, and automatic draining, so no manual water handling is needed.

The unit runs full Class B sterilisation cycles and complies with EN 13060 standards. It ensures deep sterilisation for all instrument types, including wrapped, unwrapped, solid, and hollow instruments.

The LED display system shows temperature, pressure, and cycle time in real time, making monitoring simple and clear. The compact vertical design saves space by integrating the water system on top of the autoclave.

This makes it ideal for small clinics and workspaces where space is limited. You can choose the drying time for each cycle. Options are 1, 5, or 10 minutes.

The autoclave includes Helix, Bowie and Dick, and Vacuum test cycles to confirm correct sterilisation and performance.


MAIN FUNCTIONS

USB PORT

Every Phoenix Blu autoclave includes a built in USB port to save and store sterilisation data automatically. The printer version also prints cycle records.

STAND-BY FUNCTION

Keeps the chamber warm between cycles, saving 10 to 15 minutes and reducing moisture.

DRYING

Choose drying time for each cycle: 1, 5, or 10 minutes.

12 STERILIZATION CYCLES

Cycles at 134°C and 121°C in Class B, with up to 12 combinations.

3 TEST CYCLES

Includes Helix, Bowie and Dick, and Vacuum tests.

ULTRA-FAST STEAM GENERATOR

External steam generator speeds up cycles and reduces limescale.

DOUBLE-HEAD VACUUM PUMP

High efficiency pump with fractionated vacuum phases for full Class B sterilisation.

INDEPENDENT AND INSPECTABLE TANKS

Separate tanks for distilled and used water with easy access and water quality control.

AIR / WATER SEPARATOR

Two condensers separate air and water to protect internal components.

QUICK DRAIN PIPE

Front connection system for fast and easy water loading and draining.

 

Download Catalog here


Technical Data

Specification Phoenix Blu 18 Phoenix Blu 24
Sterilization System Steam Sterilizer (Autoclave) Steam Sterilizer (Autoclave)
Medical Device Class Class IIb Class IIb
Class (UNI EN 13060) Class B Class B
External Dimensions 462 × 445 × 600 mm (W × H × D) 462 × 445 × 600 mm (W × H × D)
Weight Net: 54 kg | Gross: 56 kg Net: 56 kg | Gross: 59 kg
Sterilization Chamber 255 × 360 mm (ø × D) 255 × 460 mm (ø × D)
Trays (3 included) 285 × 190 mm 385 × 190 mm
Power Consumption 1800 W 1800 W
Voltage 220 V 220 V
Min. Support Surface Depth 500 mm 500 mm
Min. Support Surface Width 460 mm 460 mm
Min. Space for Water Loading 165 mm 165 mm
Sterilization Temperature 121°C - 134°C 121°C - 134°C
Maximum Temperature 138°C 138°C
Working Pressure 121°C: 1.0-1.3 bar (STP)
134°C: 2.0-2.4 bar (STP)
121°C: 1.0-1.3 bar (STP)
134°C: 2.0-2.4 bar (STP)
Max Working Empty -0.9 bar (STP) -0.9 bar (STP)
Maximum Pressure 2.5 bar 2.5 bar
Water Tank Capacity Distilled: 4.6 L | Used: 5.0 L Distilled: 4.6 L | Used: 5.0 L
Water Consumption per Cycle 0.30-0.55 L (15 cycles) 0.40-0.60 L (11 cycles)
Bacteriological Filter (Air) ø 56 mm | 0.3 μm capacity ø 56 mm | 0.3 μm capacity

 

 

Description

Phoenix Blu Top 18L/24L LED Autoclave with Osmosis System + Free Water Distiller

This is a Class B autoclave available in 18 liter and 24 liter capacity, designed for dental clinics, medical practices, veterinary use, and beauty centers.

This steam steriliser provides reliable sterilisation of dental instruments, surgical tools, and hollow or porous instruments. It includes a built in top mounted osmosis system with automatic water purification, automatic water filling, and automatic draining, so no manual water handling is needed.

The unit runs full Class B sterilisation cycles and complies with EN 13060 standards. It ensures deep sterilisation for all instrument types, including wrapped, unwrapped, solid, and hollow instruments.

The LED display system shows temperature, pressure, and cycle time in real time, making monitoring simple and clear. The compact vertical design saves space by integrating the water system on top of the autoclave.

This makes it ideal for small clinics and workspaces where space is limited. You can choose the drying time for each cycle. Options are 1, 5, or 10 minutes.

The autoclave includes Helix, Bowie and Dick, and Vacuum test cycles to confirm correct sterilisation and performance.


MAIN FUNCTIONS

USB PORT

Every Phoenix Blu autoclave includes a built in USB port to save and store sterilisation data automatically. The printer version also prints cycle records.

STAND-BY FUNCTION

Keeps the chamber warm between cycles, saving 10 to 15 minutes and reducing moisture.

DRYING

Choose drying time for each cycle: 1, 5, or 10 minutes.

12 STERILIZATION CYCLES

Cycles at 134°C and 121°C in Class B, with up to 12 combinations.

3 TEST CYCLES

Includes Helix, Bowie and Dick, and Vacuum tests.

ULTRA-FAST STEAM GENERATOR

External steam generator speeds up cycles and reduces limescale.

DOUBLE-HEAD VACUUM PUMP

High efficiency pump with fractionated vacuum phases for full Class B sterilisation.

INDEPENDENT AND INSPECTABLE TANKS

Separate tanks for distilled and used water with easy access and water quality control.

AIR / WATER SEPARATOR

Two condensers separate air and water to protect internal components.

QUICK DRAIN PIPE

Front connection system for fast and easy water loading and draining.

 

Download Catalog here


Technical Data

Specification Phoenix Blu 18 Phoenix Blu 24
Sterilization System Steam Sterilizer (Autoclave) Steam Sterilizer (Autoclave)
Medical Device Class Class IIb Class IIb
Class (UNI EN 13060) Class B Class B
External Dimensions 462 × 445 × 600 mm (W × H × D) 462 × 445 × 600 mm (W × H × D)
Weight Net: 54 kg | Gross: 56 kg Net: 56 kg | Gross: 59 kg
Sterilization Chamber 255 × 360 mm (ø × D) 255 × 460 mm (ø × D)
Trays (3 included) 285 × 190 mm 385 × 190 mm
Power Consumption 1800 W 1800 W
Voltage 220 V 220 V
Min. Support Surface Depth 500 mm 500 mm
Min. Support Surface Width 460 mm 460 mm
Min. Space for Water Loading 165 mm 165 mm
Sterilization Temperature 121°C - 134°C 121°C - 134°C
Maximum Temperature 138°C 138°C
Working Pressure 121°C: 1.0-1.3 bar (STP)
134°C: 2.0-2.4 bar (STP)
121°C: 1.0-1.3 bar (STP)
134°C: 2.0-2.4 bar (STP)
Max Working Empty -0.9 bar (STP) -0.9 bar (STP)
Maximum Pressure 2.5 bar 2.5 bar
Water Tank Capacity Distilled: 4.6 L | Used: 5.0 L Distilled: 4.6 L | Used: 5.0 L
Water Consumption per Cycle 0.30-0.55 L (15 cycles) 0.40-0.60 L (11 cycles)
Bacteriological Filter (Air) ø 56 mm | 0.3 μm capacity ø 56 mm | 0.3 μm capacity

 

 

Why Buy From Us

Why Buy From Us?

We get it. You've got a lot of choice when it comes to online retailers. Here's why we think you should shop with us at Zentra. 

Free Shipping within the EU. No extra charges. Ever.
Price Match Guarantee. Best prices online guaranteed.

30 Day Easy Returns. No happy with your product? we'll take it back no questions asked. Great Service. We pride ourselves on the best service, anywhere. 

Your Satisfaction Guaranteed. We handpick our products for quality, we know you'll love them. But is there is ever something wrong, we'll fix it.

Shipping

Shipping is FREE on all orders to customers within the EU. We don't want to mess around with fine print and extra charges, we like things to be simple and easy. 

Return & Refund Policy

While we fully stand by every product that we sell, we understand that sometimes you might change your mind or realise the product you ordered wasn't exactly what you were hoping for. 

That's why we offer a 14 Days Return Policy. 

If you decide you want to return an item for any reason within 14 days after receipt of your order, please email us atsales@zentra-eu.com with your order number and we will provide detailed instructions on how to process the return.

Please note, you as the customer will be responsible for paying the return shipping costs of the item(s) in your order. 

Once your return item(s) have been received and inspected at our warehouse(s), we will send you an email notification that we have processed your return payment. 

*Please note: We allow returns if the product has only been opened and inspected, but not used. Products showing signs of use, wear, or missing accessories are not eligible for refund.

We allow returns if the product has only been opened and inspected, but not used.

If you decide you want to return your order, please email us atsales@zentra-eu.com with your order number and we will assist you. We want to make this as simple of a process as possible for you.

Please do not ship your return until we have confirmed the correct return address with you.

All standard returns must be sent to our central return address:

Zentra Online - Returns Department
Groeneweg 32c
1861 PH Bergen
The Netherlands

In some cases, especially for large or technical equipment, we may ask you to ship directly to the manufacturer’s warehouse. Our customer service team will confirm the correct return location with you by email before you send back the product.

Orders Not Received

If your order has not arrived within the estimated delivery time, please contact us atsales@zentra-eu.com with your order number. We will investigate with the courier and, if the package is confirmed lost, we will offer you either a replacement or a full refund.

Damages

If the product is damaged, you must make note of it immediately when signing for delivery and send photos to sales@zentra-eu.com the day of delivery.

Zentra will pay for shipping defective, damaged, or incorrect merchandise at our cost. 

Remember to keep all the original packaging for any items that need to be returned. All returns need to be authorized by our customer service department prior to being processed. 

We will ensure you get the product you ordered, undamaged, as soon as possible. Items that become damaged after use are non-refundable unless specified under warranty. 

Cancellations 

If you would like to cancel an order, please email or call us immediately.

Orders canceled before shipment will receive a full refund. Orders canceled after shipment fall under our 14-day return policy and may be subject to return shipping costs.

Timeframes for Reporting Issues

To make sure we can help you quickly, please report issues within the following timeframes:

  • Change of Mind: 14 days from the date you received the order.

  • Damaged Items: On the day of delivery (please send photos the same day).

  • Wrong Product Received: Within 7 days of delivery.

  • Faulty Product (after delivery): Within 14 days of delivery, unless covered by warranty.

  • Order Not Received: Within 30 days from the order date.

  • Order Cancellation: Before the order has been shipped for a full refund; after shipment, our 14-day return policy applies.

Refund Processing Time

Once we get your returned item, we’ll check it and then send your money back. This usually takes 5 to 7 days. We’ll let you know as soon as your refund is on the way.

Refund Method

All refunds will be made to your original payment method unless otherwise agreed in writing.

Other Return Policy Notes: 

All products sold on our website follow this 14-day return policy unless explicitly stated otherwise in the product description.

Certified pre-owned or used products are not eligible for return unless they arrive damaged or defective.

Orders placed for short-term or temporary use (e.g., trade shows, promotional events) are generally not eligible for return unless the product arrives damaged or is not as described.

Faulty Items After Delivery

If your item stops working within 14 days of delivery and is not due to misuse or damage, please contact us for a replacement or refund. Items may also be covered by the warranty, see our Product Warranty Policy for details.

Description

Phoenix Blu Top 18L/24L LED Autoclave with Osmosis System + Free Water Distiller

This is a Class B autoclave available in 18 liter and 24 liter capacity, designed for dental clinics, medical practices, veterinary use, and beauty centers.

This steam steriliser provides reliable sterilisation of dental instruments, surgical tools, and hollow or porous instruments. It includes a built in top mounted osmosis system with automatic water purification, automatic water filling, and automatic draining, so no manual water handling is needed.

The unit runs full Class B sterilisation cycles and complies with EN 13060 standards. It ensures deep sterilisation for all instrument types, including wrapped, unwrapped, solid, and hollow instruments.

The LED display system shows temperature, pressure, and cycle time in real time, making monitoring simple and clear. The compact vertical design saves space by integrating the water system on top of the autoclave.

This makes it ideal for small clinics and workspaces where space is limited. You can choose the drying time for each cycle. Options are 1, 5, or 10 minutes.

The autoclave includes Helix, Bowie and Dick, and Vacuum test cycles to confirm correct sterilisation and performance.


MAIN FUNCTIONS

USB PORT

Every Phoenix Blu autoclave includes a built in USB port to save and store sterilisation data automatically. The printer version also prints cycle records.

STAND-BY FUNCTION

Keeps the chamber warm between cycles, saving 10 to 15 minutes and reducing moisture.

DRYING

Choose drying time for each cycle: 1, 5, or 10 minutes.

12 STERILIZATION CYCLES

Cycles at 134°C and 121°C in Class B, with up to 12 combinations.

3 TEST CYCLES

Includes Helix, Bowie and Dick, and Vacuum tests.

ULTRA-FAST STEAM GENERATOR

External steam generator speeds up cycles and reduces limescale.

DOUBLE-HEAD VACUUM PUMP

High efficiency pump with fractionated vacuum phases for full Class B sterilisation.

INDEPENDENT AND INSPECTABLE TANKS

Separate tanks for distilled and used water with easy access and water quality control.

AIR / WATER SEPARATOR

Two condensers separate air and water to protect internal components.

QUICK DRAIN PIPE

Front connection system for fast and easy water loading and draining.

 

Download Catalog here


Technical Data

Specification Phoenix Blu 18 Phoenix Blu 24
Sterilization System Steam Sterilizer (Autoclave) Steam Sterilizer (Autoclave)
Medical Device Class Class IIb Class IIb
Class (UNI EN 13060) Class B Class B
External Dimensions 462 × 445 × 600 mm (W × H × D) 462 × 445 × 600 mm (W × H × D)
Weight Net: 54 kg | Gross: 56 kg Net: 56 kg | Gross: 59 kg
Sterilization Chamber 255 × 360 mm (ø × D) 255 × 460 mm (ø × D)
Trays (3 included) 285 × 190 mm 385 × 190 mm
Power Consumption 1800 W 1800 W
Voltage 220 V 220 V
Min. Support Surface Depth 500 mm 500 mm
Min. Support Surface Width 460 mm 460 mm
Min. Space for Water Loading 165 mm 165 mm
Sterilization Temperature 121°C - 134°C 121°C - 134°C
Maximum Temperature 138°C 138°C
Working Pressure 121°C: 1.0-1.3 bar (STP)
134°C: 2.0-2.4 bar (STP)
121°C: 1.0-1.3 bar (STP)
134°C: 2.0-2.4 bar (STP)
Max Working Empty -0.9 bar (STP) -0.9 bar (STP)
Maximum Pressure 2.5 bar 2.5 bar
Water Tank Capacity Distilled: 4.6 L | Used: 5.0 L Distilled: 4.6 L | Used: 5.0 L
Water Consumption per Cycle 0.30-0.55 L (15 cycles) 0.40-0.60 L (11 cycles)
Bacteriological Filter (Air) ø 56 mm | 0.3 μm capacity ø 56 mm | 0.3 μm capacity

 

 

Why Buy From Us

Why Buy From Us?

We get it. You've got a lot of choice when it comes to online retailers. Here's why we think you should shop with us at Zentra. 

Free Shipping within the EU. No extra charges. Ever.
Price Match Guarantee. Best prices online guaranteed.

30 Day Easy Returns. No happy with your product? we'll take it back no questions asked. Great Service. We pride ourselves on the best service, anywhere. 

Your Satisfaction Guaranteed. We handpick our products for quality, we know you'll love them. But is there is ever something wrong, we'll fix it.

Shipping

Shipping is FREE on all orders to customers within the EU. We don't want to mess around with fine print and extra charges, we like things to be simple and easy. 

Return & Refund Policy

While we fully stand by every product that we sell, we understand that sometimes you might change your mind or realise the product you ordered wasn't exactly what you were hoping for. 

That's why we offer a 14 Days Return Policy. 

If you decide you want to return an item for any reason within 14 days after receipt of your order, please email us atsales@zentra-eu.com with your order number and we will provide detailed instructions on how to process the return.

Please note, you as the customer will be responsible for paying the return shipping costs of the item(s) in your order. 

Once your return item(s) have been received and inspected at our warehouse(s), we will send you an email notification that we have processed your return payment. 

*Please note: We allow returns if the product has only been opened and inspected, but not used. Products showing signs of use, wear, or missing accessories are not eligible for refund.

We allow returns if the product has only been opened and inspected, but not used.

If you decide you want to return your order, please email us atsales@zentra-eu.com with your order number and we will assist you. We want to make this as simple of a process as possible for you.

Please do not ship your return until we have confirmed the correct return address with you.

All standard returns must be sent to our central return address:

Zentra Online - Returns Department
Groeneweg 32c
1861 PH Bergen
The Netherlands

In some cases, especially for large or technical equipment, we may ask you to ship directly to the manufacturer’s warehouse. Our customer service team will confirm the correct return location with you by email before you send back the product.

Orders Not Received

If your order has not arrived within the estimated delivery time, please contact us atsales@zentra-eu.com with your order number. We will investigate with the courier and, if the package is confirmed lost, we will offer you either a replacement or a full refund.

Damages

If the product is damaged, you must make note of it immediately when signing for delivery and send photos to sales@zentra-eu.com the day of delivery.

Zentra will pay for shipping defective, damaged, or incorrect merchandise at our cost. 

Remember to keep all the original packaging for any items that need to be returned. All returns need to be authorized by our customer service department prior to being processed. 

We will ensure you get the product you ordered, undamaged, as soon as possible. Items that become damaged after use are non-refundable unless specified under warranty. 

Cancellations 

If you would like to cancel an order, please email or call us immediately.

Orders canceled before shipment will receive a full refund. Orders canceled after shipment fall under our 14-day return policy and may be subject to return shipping costs.

Timeframes for Reporting Issues

To make sure we can help you quickly, please report issues within the following timeframes:

  • Change of Mind: 14 days from the date you received the order.

  • Damaged Items: On the day of delivery (please send photos the same day).

  • Wrong Product Received: Within 7 days of delivery.

  • Faulty Product (after delivery): Within 14 days of delivery, unless covered by warranty.

  • Order Not Received: Within 30 days from the order date.

  • Order Cancellation: Before the order has been shipped for a full refund; after shipment, our 14-day return policy applies.

Refund Processing Time

Once we get your returned item, we’ll check it and then send your money back. This usually takes 5 to 7 days. We’ll let you know as soon as your refund is on the way.

Refund Method

All refunds will be made to your original payment method unless otherwise agreed in writing.

Other Return Policy Notes: 

All products sold on our website follow this 14-day return policy unless explicitly stated otherwise in the product description.

Certified pre-owned or used products are not eligible for return unless they arrive damaged or defective.

Orders placed for short-term or temporary use (e.g., trade shows, promotional events) are generally not eligible for return unless the product arrives damaged or is not as described.

Faulty Items After Delivery

If your item stops working within 14 days of delivery and is not due to misuse or damage, please contact us for a replacement or refund. Items may also be covered by the warranty, see our Product Warranty Policy for details.