{"product_id":"kern-inverted-fluorescence-microscope-ocm-166-free-c-mount-adapter","title":"KERN Inverted Fluorescence Microscope OCM 166 - Trinocular 10x 20x 40x","description":"\u003ch3 data-start=\"164\" data-end=\"217\"\u003e\u003cstrong\u003eKERN OCM 166\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"219\" data-end=\"393\"\u003eThe OCM 166 is an inverted fluorescence microscope with a stable build and a large working distance. This makes it suitable for monitoring and analysing cell cultures.\u003c\/p\u003e\n\u003cp data-start=\"395\" data-end=\"741\"\u003eIt uses a strong 30 W halogen lamp for bright field illumination. For fluorescence work, it has an Osram 100 W HBO epi fluorescence unit, which provides powerful and clear light for fluorescence samples. The Abbe condenser with 0.3 aperture and a working distance of 72 mm helps direct the light correctly in both bright field and fluorescence.\u003c\/p\u003e\n\u003cp data-start=\"743\" data-end=\"1077\"\u003eA trinocular eyepiece tube is fitted as standard. The stage includes a 110 mm specimen holder, allowing smooth and effective handling of samples. Extra brackets for petri dishes are supplied or available as accessories. Other accessories, such as eyepieces, objectives, specimen holders, and phase contrast units, can also be added.\u003c\/p\u003e\n\u003cp data-start=\"1079\" data-end=\"1352\"\u003eThe microscope is delivered with a \u003cstrong data-start=\"1114\" data-end=\"1147\"\u003efree OBB-A1515 camera adapter\u003c\/strong\u003e. This C-mount 0.5x adapter with adjustable focus connects a microscope camera to the trinocular tube, making it easy to capture and document images. A dust cover and user instructions are also included.\u003c\/p\u003e\n\u003ch4 data-start=\"1354\" data-end=\"1369\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-start=\"1354\" data-end=\"1369\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul data-start=\"1370\" data-end=\"1946\"\u003e\n\u003cli data-start=\"1370\" data-end=\"1422\"\u003e\n\u003cp data-start=\"1372\" data-end=\"1422\"\u003eInverted microscope with large working distance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1423\" data-end=\"1476\"\u003e\n\u003cp data-start=\"1425\" data-end=\"1476\"\u003e30 W halogen light for bright field illumination.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1477\" data-end=\"1544\"\u003e\n\u003cp data-start=\"1479\" data-end=\"1544\"\u003eOsram 100 W HBO epi fluorescence unit for fluorescence imaging.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1545\" data-end=\"1609\"\u003e\n\u003cp data-start=\"1547\" data-end=\"1609\"\u003eAbbe condenser with 0.3 aperture and 72 mm working distance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1610\" data-end=\"1639\"\u003e\n\u003cp data-start=\"1612\" data-end=\"1639\"\u003eTrinocular eyepiece tube.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1640\" data-end=\"1689\"\u003e\n\u003cp data-start=\"1642\" data-end=\"1689\"\u003eMechanical stage with 110 mm specimen holder.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1690\" data-end=\"1751\"\u003e\n\u003cp data-start=\"1692\" data-end=\"1751\"\u003ePetri dish brackets included or available as accessories.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1752\" data-end=\"1809\"\u003e\n\u003cp data-start=\"1754\" data-end=\"1809\"\u003eFree OBB-A1515 camera adapter for microscope cameras.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1810\" data-end=\"1899\"\u003e\n\u003cp data-start=\"1812\" data-end=\"1899\"\u003eAccessories available: eyepieces, objectives, specimen holders, phase contrast units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1900\" data-end=\"1946\"\u003e\n\u003cp data-start=\"1902\" data-end=\"1946\"\u003eSupplied with dust cover and instructions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"1948\" data-end=\"1967\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-start=\"1948\" data-end=\"1967\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-start=\"1968\" data-end=\"2275\"\u003eThe OCM 166 is used for research and breeding of cell and tissue cultures. It is also used in laboratories, inpatient facilities, and by health authorities. Typical samples include cell cultures, tissue, and microorganisms, as well as fluorescence methods like immunofluorescence, FISH, and DAPI staining.\u003c\/p\u003e\n\u003ch4 data-start=\"2277\" data-end=\"2298\"\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4 data-start=\"2277\" data-end=\"2298\"\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul data-start=\"2299\" data-end=\"2880\"\u003e\n\u003cli data-start=\"2299\" data-end=\"2328\"\u003e\n\u003cp data-start=\"2301\" data-end=\"2328\"\u003eOptical system: Infinity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2329\" data-end=\"2355\"\u003e\n\u003cp data-start=\"2331\" data-end=\"2355\"\u003eTube type: Trinocular.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2356\" data-end=\"2386\"\u003e\n\u003cp data-start=\"2358\" data-end=\"2386\"\u003eOcular magnification: 10x.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2387\" data-end=\"2418\"\u003e\n\u003cp data-start=\"2389\" data-end=\"2418\"\u003eOcular visual field: 22 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2419\" data-end=\"2466\"\u003e\n\u003cp data-start=\"2421\" data-end=\"2466\"\u003eStandard objectives: 10×, 20×, 40×, PH 20×.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2467\" data-end=\"2499\"\u003e\n\u003cp data-start=\"2469\" data-end=\"2499\"\u003eLens quality: Infinity Plan.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2500\" data-end=\"2527\"\u003e\n\u003cp data-start=\"2502\" data-end=\"2527\"\u003eNosepiece positions: 5.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2528\" data-end=\"2577\"\u003e\n\u003cp data-start=\"2530\" data-end=\"2577\"\u003eIlluminance: Reflected and transmitted light.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2578\" data-end=\"2627\"\u003e\n\u003cp data-start=\"2580\" data-end=\"2627\"\u003eIllumination type transmitted: Halogen, 30 W.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2628\" data-end=\"2671\"\u003e\n\u003cp data-start=\"2630\" data-end=\"2671\"\u003eIllumination type incident: HBO, 100 W.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2672\" data-end=\"2733\"\u003e\n\u003cp data-start=\"2674\" data-end=\"2733\"\u003eFluorescent unit: Ultraviolet, Violet, Blue, Green (HBO).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2734\" data-end=\"2766\"\u003e\n\u003cp data-start=\"2736\" data-end=\"2766\"\u003eCondenser: Abbe, 0.3, fixed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2767\" data-end=\"2811\"\u003e\n\u003cp data-start=\"2769\" data-end=\"2811\"\u003eFocusing: Coaxial coarse and fine drive.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2812\" data-end=\"2842\"\u003e\n\u003cp data-start=\"2814\" data-end=\"2842\"\u003eFine focus step: 0.002 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2843\" data-end=\"2880\"\u003e\n\u003cp data-start=\"2845\" data-end=\"2880\"\u003eSize (W×D×H): 782 × 304 × 530 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2882\" data-end=\"2938\"\u003e \u003c\/p\u003e\n\u003ch4 data-start=\"2882\" data-end=\"2938\"\u003e\u003cstrong data-start=\"2882\" data-end=\"2936\"\u003eFree Included Accessory - OBB-A1515 Camera Adapter\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul data-start=\"2939\" data-end=\"3091\"\u003e\n\u003cli data-start=\"2939\" data-end=\"2965\"\u003e\n\u003cp data-start=\"2941\" data-end=\"2965\"\u003eAdapter type: C-Mount.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2966\" data-end=\"2990\"\u003e\n\u003cp data-start=\"2968\" data-end=\"2990\"\u003eMagnification: 0.5x.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2991\" data-end=\"3010\"\u003e\n\u003cp data-start=\"2993\" data-end=\"3010\"\u003eFocusable: Yes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3011\" data-end=\"3058\"\u003e\n\u003cp data-start=\"3013\" data-end=\"3058\"\u003eSupported camera types: Microscope cameras.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3059\" data-end=\"3091\"\u003e\n\u003cp data-start=\"3061\" data-end=\"3091\"\u003eNet weight: approx. 0.30 kg.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0946\/5105\/6463\/files\/SL_OCM_166_BROCHURE.pdf?v=1759171907\"\u003eBrochure\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003ca href=\"https:\/\/zentra-eu.com\/pages\/downloads\" rel=\"noopener\" target=\"_blank\"\u003eCertifications\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0946\/5105\/6463\/files\/TD_OCM_166_data_page-0001.jpg?v=1759171859\" alt=\"\" style=\"width: 100%; max-width: 1000px; height: auto; display: block; margin: 0 auto;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0946\/5105\/6463\/files\/TD_OCM_166_data_page-0002.jpg?v=1759171859\" alt=\"\" style=\"width: 100%; max-width: 1000px; height: auto; display: block; margin: 0 auto;\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e**All our products are brand new, shipped in the original packaging, and include manufacturer warranty**\u003c\/p\u003e","brand":"Kern \u0026 Sohn","offers":[{"title":"Default Title","offer_id":56033931854159,"sku":"OCM-166","price":12523.5,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0946\/5105\/6463\/files\/OCM-165-166-167-168.jpg?v=1759166953","url":"https:\/\/zentra-eu.com\/en\/products\/kern-inverted-fluorescence-microscope-ocm-166-free-c-mount-adapter","provider":"Zentra ","version":"1.0","type":"link"}