{"title":"Mini Centrifuges \u0026 Vortex Mixers","description":"","products":[{"product_id":"biosan-cvp-2-mini-centrifuge-vortex","title":"Biosan CVP-2 Mini Centrifuge Vortex","description":"\u003ch3 data-section-id=\"840wl1\" data-start=\"0\" data-end=\"53\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"4\" data-end=\"53\"\u003eBiosan CVP-2 Centrifuge Vortex for PCR Plates\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"55\" data-end=\"395\"\u003eCentrifuge vortex mixer designed for PCR sample preparation, DNA analysis, reagent mixing, PCR workflow automation, and molecular biology applications. Suitable for PCR laboratories, molecular biology laboratories, biotechnology laboratories, diagnostic laboratories, and research facilities working with PCR plates and microvolume samples.\u003c\/p\u003e\n\u003cp data-start=\"397\" data-end=\"744\"\u003eThe Biosan CVP-2 combines centrifugation and vortex mixing in a single device. It uses Biosan's Spin-Mix-Spin (SMS) algorithm to spin down reagents, mix samples, and spin them down again, helping reduce preparation errors during PCR workflows. The unit can process two PCR plates simultaneously and combines four operating modes in one instrument.\u003c\/p\u003e\n\u003ch4 data-start=\"746\" data-end=\"769\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"751\" data-end=\"769\"\u003eTechnical Data\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul data-start=\"771\" data-end=\"1037\"\u003e\n\u003cli data-section-id=\"xprctl\" data-start=\"771\" data-end=\"806\"\u003eSpeed range from 300 to 1,500 RPM\u003c\/li\u003e\n\u003cli data-section-id=\"1vu2fe4\" data-start=\"807\" data-end=\"849\"\u003eVortex speed range from 300 to 1,200 RPM\u003c\/li\u003e\n\u003cli data-section-id=\"1ffvgrs\" data-start=\"850\" data-end=\"872\"\u003eMaximum RCF: 225 × g\u003c\/li\u003e\n\u003cli data-section-id=\"upx75z\" data-start=\"873\" data-end=\"916\"\u003eSMS cycle regulation from 1 to 999 cycles\u003c\/li\u003e\n\u003cli data-section-id=\"1xdarqa\" data-start=\"917\" data-end=\"960\"\u003eCentrifugation timer from 0 to 30 minutes\u003c\/li\u003e\n\u003cli data-section-id=\"1o9wdit\" data-start=\"961\" data-end=\"996\"\u003eVortex timer from 0 to 60 seconds\u003c\/li\u003e\n\u003cli data-section-id=\"9p0sex\" data-start=\"997\" data-end=\"1010\"\u003eLCD display\u003c\/li\u003e\n\u003cli data-section-id=\"1xsd40k\" data-start=\"1011\" data-end=\"1037\"\u003eChamber diameter: 210 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"1039\" data-end=\"1060\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1044\" data-end=\"1060\"\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul data-start=\"1062\" data-end=\"1270\"\u003e\n\u003cli data-section-id=\"1ikm86u\" data-start=\"1062\" data-end=\"1086\"\u003ePCR sample preparation\u003c\/li\u003e\n\u003cli data-section-id=\"k7n4s1\" data-start=\"1087\" data-end=\"1101\"\u003eDNA analysis\u003c\/li\u003e\n\u003cli data-section-id=\"13xtere\" data-start=\"1102\" data-end=\"1118\"\u003eReagent mixing\u003c\/li\u003e\n\u003cli data-section-id=\"13rw781\" data-start=\"1119\" data-end=\"1144\"\u003ePCR workflow processing\u003c\/li\u003e\n\u003cli data-section-id=\"1dli1jn\" data-start=\"1145\" data-end=\"1174\"\u003eMolecular biology workflows\u003c\/li\u003e\n\u003cli data-section-id=\"fqobz7\" data-start=\"1175\" data-end=\"1203\"\u003eBiotechnology applications\u003c\/li\u003e\n\u003cli data-section-id=\"9kok0q\" data-start=\"1204\" data-end=\"1235\"\u003eDiagnostic laboratory testing\u003c\/li\u003e\n\u003cli data-section-id=\"1fc6wrf\" data-start=\"1236\" data-end=\"1270\"\u003eResearch laboratory applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"1272\" data-end=\"1293\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1277\" data-end=\"1293\"\u003eKey Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul data-start=\"1295\" data-end=\"1685\"\u003e\n\u003cli data-section-id=\"8d21ee\" data-start=\"1295\" data-end=\"1384\"\u003eCentrifuge, vortex mixer, combined centrifuge vortex mode, and SMS cycler in one device\u003c\/li\u003e\n\u003cli data-section-id=\"1e1x5gv\" data-start=\"1385\" data-end=\"1423\"\u003eBiosan Spin-Mix-Spin (SMS) algorithm\u003c\/li\u003e\n\u003cli data-section-id=\"hrkbf9\" data-start=\"1424\" data-end=\"1463\"\u003eProcesses 2 PCR plates simultaneously\u003c\/li\u003e\n\u003cli data-section-id=\"rqnwgf\" data-start=\"1464\" data-end=\"1500\"\u003eCompatible with 96 well PCR plates\u003c\/li\u003e\n\u003cli data-section-id=\"u5eydv\" data-start=\"1501\" data-end=\"1562\"\u003eCompatible with 384 well PCR plates using optional adapters\u003c\/li\u003e\n\u003cli data-section-id=\"1ng82y4\" data-start=\"1563\" data-end=\"1608\"\u003eAdjustable centrifugation and vortex speeds\u003c\/li\u003e\n\u003cli data-section-id=\"1d7jbmy\" data-start=\"1609\" data-end=\"1636\"\u003eFully automatic operation\u003c\/li\u003e\n\u003cli data-section-id=\"13vtv12\" data-start=\"1637\" data-end=\"1685\"\u003eDesigned for PCR and DNA analysis laboratories\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cnoscript class=\"loading-lazy\"\u003e\n  \u003ciframe loading=\"lazy\" width=\"560\" height=\"315\" style=\"width: 100%; max-width: 100%; height: auto; aspect-ratio: 16\/9;\" src=\"https:\/\/www.youtube.com\/embed\/efUE2HQbA5A?si=Dxdn3fMstmpuKhVM\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" allowfullscreen\u003e\u003c\/iframe\u003e\n\u003c\/noscript\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cnoscript class=\"loading-lazy\"\u003e\n  \u003ciframe loading=\"lazy\" width=\"560\" height=\"315\" style=\"width: 100%; max-width: 100%; height: auto; aspect-ratio: 16\/9;\" src=\"https:\/\/www.youtube.com\/embed\/Ij7jZANIwuk?si=o9vK20EzaCUR6v_J\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" allowfullscreen\u003e\u003c\/iframe\u003e\n\u003c\/noscript\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Biosan","offers":[{"title":"Default Title","offer_id":57791576572239,"sku":"CVP-2","price":1330.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0946\/5105\/6463\/files\/centrifuge-vortex-for-pcr-plates-cvp-2.png.1200x1200_q85.png?v=1779898529"},{"product_id":"biosan-msc-3000-high-speed-centrifuge-vortex","title":"Biosan MSC-3000 High Speed Centrifuge Vortex","description":"\u003ch3 data-section-id=\"12rbof3\" data-start=\"0\" data-end=\"72\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"4\" data-end=\"72\"\u003eBiosan MSC-3000 Minicentrifuge Vortex for PCR Sample Preparation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"74\" data-end=\"394\"\u003eMinicentrifuge vortex designed for PCR sample preparation, DNA analysis, reagent mixing, sample spin down, and molecular biology workflows. Suitable for PCR laboratories, molecular biology laboratories, biotechnology laboratories, diagnostic laboratories, and research facilities working with microtubes and PCR samples.\u003c\/p\u003e\n\u003cp data-start=\"396\" data-end=\"771\"\u003eThe Biosan MSC-3000 combines centrifugation and vortex mixing in a single device. Using Biosan's Spin-Mix-Spin (SMS) algorithm, the unit automatically spins samples down, mixes them, and spins them again to help reduce preparation errors during PCR workflows. The system can process up to 12 microtubes simultaneously and combines four laboratory functions in one instrument.\u003c\/p\u003e\n\u003ch4 data-start=\"773\" data-end=\"796\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"778\" data-end=\"796\"\u003eTechnical Data\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul data-start=\"798\" data-end=\"1081\"\u003e\n\u003cli data-section-id=\"12sybjp\" data-start=\"798\" data-end=\"835\"\u003eSpeed range from 1,000 to 3,500 RPM\u003c\/li\u003e\n\u003cli data-section-id=\"1gane91\" data-start=\"836\" data-end=\"858\"\u003eMaximum RCF: 800 × g\u003c\/li\u003e\n\u003cli data-section-id=\"1mbrssa\" data-start=\"859\" data-end=\"899\"\u003eSpin timer from 1 second to 99 minutes\u003c\/li\u003e\n\u003cli data-section-id=\"1oynz75\" data-start=\"900\" data-end=\"935\"\u003eVortex timer from 0 to 20 seconds\u003c\/li\u003e\n\u003cli data-section-id=\"upx75z\" data-start=\"936\" data-end=\"979\"\u003eSMS cycle regulation from 1 to 999 cycles\u003c\/li\u003e\n\u003cli data-section-id=\"zwbqpk\" data-start=\"980\" data-end=\"1031\"\u003eThree vortex intensity levels: soft, medium, hard\u003c\/li\u003e\n\u003cli data-section-id=\"9p0sex\" data-start=\"1032\" data-end=\"1045\"\u003eLCD display\u003c\/li\u003e\n\u003cli data-section-id=\"1f7esbb\" data-start=\"1046\" data-end=\"1081\"\u003eAutomatic stop when lid is opened\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"1083\" data-end=\"1104\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1088\" data-end=\"1104\"\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul data-start=\"1106\" data-end=\"1307\"\u003e\n\u003cli data-section-id=\"1ikm86u\" data-start=\"1106\" data-end=\"1130\"\u003ePCR sample preparation\u003c\/li\u003e\n\u003cli data-section-id=\"k7n4s1\" data-start=\"1131\" data-end=\"1145\"\u003eDNA analysis\u003c\/li\u003e\n\u003cli data-section-id=\"13xtere\" data-start=\"1146\" data-end=\"1162\"\u003eReagent mixing\u003c\/li\u003e\n\u003cli data-section-id=\"dbi3p4\" data-start=\"1163\" data-end=\"1181\"\u003eSample spin down\u003c\/li\u003e\n\u003cli data-section-id=\"1dli1jn\" data-start=\"1182\" data-end=\"1211\"\u003eMolecular biology workflows\u003c\/li\u003e\n\u003cli data-section-id=\"fqobz7\" data-start=\"1212\" data-end=\"1240\"\u003eBiotechnology applications\u003c\/li\u003e\n\u003cli data-section-id=\"9kok0q\" data-start=\"1241\" data-end=\"1272\"\u003eDiagnostic laboratory testing\u003c\/li\u003e\n\u003cli data-section-id=\"1fc6wrf\" data-start=\"1273\" data-end=\"1307\"\u003eResearch laboratory applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"1309\" data-end=\"1330\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1314\" data-end=\"1330\"\u003eKey Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul data-start=\"1332\" data-end=\"1717\"\u003e\n\u003cli data-section-id=\"8d21ee\" data-start=\"1332\" data-end=\"1421\"\u003eCentrifuge, vortex mixer, combined centrifuge vortex mode, and SMS cycler in one device\u003c\/li\u003e\n\u003cli data-section-id=\"1e1x5gv\" data-start=\"1422\" data-end=\"1460\"\u003eBiosan Spin-Mix-Spin (SMS) algorithm\u003c\/li\u003e\n\u003cli data-section-id=\"1niwc23\" data-start=\"1461\" data-end=\"1507\"\u003eProcesses up to 12 microtubes simultaneously\u003c\/li\u003e\n\u003cli data-section-id=\"1yzwjex\" data-start=\"1508\" data-end=\"1545\"\u003eAutomatic sample preparation cycles\u003c\/li\u003e\n\u003cli data-section-id=\"dy804d\" data-start=\"1546\" data-end=\"1593\"\u003eAdjustable centrifugation and vortex settings\u003c\/li\u003e\n\u003cli data-section-id=\"1gfhzht\" data-start=\"1594\" data-end=\"1627\"\u003eThree vortex mixing intensities\u003c\/li\u003e\n\u003cli data-section-id=\"z2iyqg\" data-start=\"1628\" data-end=\"1668\"\u003eCompatible with multiple rotor options\u003c\/li\u003e\n\u003cli data-section-id=\"13vtv12\" data-start=\"1669\" data-end=\"1717\"\u003eDesigned for PCR and DNA analysis laboratories\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cnoscript class=\"loading-lazy\"\u003e\n  \u003ciframe loading=\"lazy\" width=\"560\" height=\"315\" style=\"width: 100%; max-width: 100%; height: auto; aspect-ratio: 16\/9;\" src=\"https:\/\/www.youtube.com\/embed\/bVct3_I6jlo?si=zeO69StGwI4HUrjF\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" allowfullscreen\u003e\u003c\/iframe\u003e\n\u003c\/noscript\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Biosan","offers":[{"title":"Default Title","offer_id":57791608357199,"sku":"MSC-3000","price":580.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0946\/5105\/6463\/files\/msc_3000_front.jpg.1200x1200_q85.jpg?v=1779899177"},{"product_id":"biosan-msc-6000-high-speed-centrifuge-vortex","title":"Biosan MSC-6000 Mini Centrifuge Vortex","description":"\u003ch3 data-section-id=\"1695l0a\" data-start=\"0\" data-end=\"72\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"4\" data-end=\"72\"\u003eBiosan MSC-6000 Minicentrifuge Vortex for PCR Sample Preparation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"74\" data-end=\"394\"\u003eMinicentrifuge vortex designed for PCR sample preparation, DNA analysis, reagent mixing, sample spin down, and molecular biology workflows. Suitable for PCR laboratories, molecular biology laboratories, biotechnology laboratories, diagnostic laboratories, and research facilities working with microtubes and PCR samples.\u003c\/p\u003e\n\u003cp data-start=\"396\" data-end=\"771\"\u003eThe Biosan MSC-6000 combines centrifugation and vortex mixing in a single device. Using Biosan's Spin-Mix-Spin (SMS) algorithm, the unit automatically spins samples down, mixes them, and spins them again to help reduce preparation errors during PCR workflows. The system can process up to 12 microtubes simultaneously and combines four laboratory functions in one instrument.\u003c\/p\u003e\n\u003ch4 data-start=\"773\" data-end=\"796\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"778\" data-end=\"796\"\u003eTechnical Data\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul data-start=\"798\" data-end=\"1072\"\u003e\n\u003cli data-section-id=\"6tptkl\" data-start=\"798\" data-end=\"835\"\u003eSpeed range from 1,000 to 6,000 RPM\u003c\/li\u003e\n\u003cli data-section-id=\"mt7q51\" data-start=\"836\" data-end=\"860\"\u003eMaximum RCF: 2,350 × g\u003c\/li\u003e\n\u003cli data-section-id=\"sk87ll\" data-start=\"861\" data-end=\"901\"\u003eSpin timer from 1 second to 30 minutes\u003c\/li\u003e\n\u003cli data-section-id=\"1oynz75\" data-start=\"902\" data-end=\"937\"\u003eVortex timer from 0 to 20 seconds\u003c\/li\u003e\n\u003cli data-section-id=\"upx75z\" data-start=\"938\" data-end=\"981\"\u003eSMS cycle regulation from 1 to 999 cycles\u003c\/li\u003e\n\u003cli data-section-id=\"zwbqpk\" data-start=\"982\" data-end=\"1033\"\u003eThree vortex intensity levels: soft, medium, hard\u003c\/li\u003e\n\u003cli data-section-id=\"9p0sex\" data-start=\"1034\" data-end=\"1047\"\u003eLCD display\u003c\/li\u003e\n\u003cli data-section-id=\"1awd4r\" data-start=\"1048\" data-end=\"1072\"\u003eLid lock safety system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"1074\" data-end=\"1095\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1079\" data-end=\"1095\"\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul data-start=\"1097\" data-end=\"1298\"\u003e\n\u003cli data-section-id=\"1ikm86u\" data-start=\"1097\" data-end=\"1121\"\u003ePCR sample preparation\u003c\/li\u003e\n\u003cli data-section-id=\"k7n4s1\" data-start=\"1122\" data-end=\"1136\"\u003eDNA analysis\u003c\/li\u003e\n\u003cli data-section-id=\"13xtere\" data-start=\"1137\" data-end=\"1153\"\u003eReagent mixing\u003c\/li\u003e\n\u003cli data-section-id=\"dbi3p4\" data-start=\"1154\" data-end=\"1172\"\u003eSample spin down\u003c\/li\u003e\n\u003cli data-section-id=\"1dli1jn\" data-start=\"1173\" data-end=\"1202\"\u003eMolecular biology workflows\u003c\/li\u003e\n\u003cli data-section-id=\"fqobz7\" data-start=\"1203\" data-end=\"1231\"\u003eBiotechnology applications\u003c\/li\u003e\n\u003cli data-section-id=\"9kok0q\" data-start=\"1232\" data-end=\"1263\"\u003eDiagnostic laboratory testing\u003c\/li\u003e\n\u003cli data-section-id=\"1fc6wrf\" data-start=\"1264\" data-end=\"1298\"\u003eResearch laboratory applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"1300\" data-end=\"1321\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1305\" data-end=\"1321\"\u003eKey Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul data-start=\"1323\" data-end=\"1708\"\u003e\n\u003cli data-section-id=\"8d21ee\" data-start=\"1323\" data-end=\"1412\"\u003eCentrifuge, vortex mixer, combined centrifuge vortex mode, and SMS cycler in one device\u003c\/li\u003e\n\u003cli data-section-id=\"1e1x5gv\" data-start=\"1413\" data-end=\"1451\"\u003eBiosan Spin-Mix-Spin (SMS) algorithm\u003c\/li\u003e\n\u003cli data-section-id=\"1niwc23\" data-start=\"1452\" data-end=\"1498\"\u003eProcesses up to 12 microtubes simultaneously\u003c\/li\u003e\n\u003cli data-section-id=\"1yzwjex\" data-start=\"1499\" data-end=\"1536\"\u003eAutomatic sample preparation cycles\u003c\/li\u003e\n\u003cli data-section-id=\"dy804d\" data-start=\"1537\" data-end=\"1584\"\u003eAdjustable centrifugation and vortex settings\u003c\/li\u003e\n\u003cli data-section-id=\"1gfhzht\" data-start=\"1585\" data-end=\"1618\"\u003eThree vortex mixing intensities\u003c\/li\u003e\n\u003cli data-section-id=\"z2iyqg\" data-start=\"1619\" data-end=\"1659\"\u003eCompatible with multiple rotor options\u003c\/li\u003e\n\u003cli data-section-id=\"13vtv12\" data-start=\"1660\" data-end=\"1708\"\u003eDesigned for PCR and DNA analysis laboratories\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cnoscript class=\"loading-lazy\"\u003e\n  \u003ciframe loading=\"lazy\" width=\"560\" height=\"315\" style=\"width: 100%; max-width: 100%; height: auto; aspect-ratio: 16\/9;\" src=\"https:\/\/www.youtube.com\/embed\/n0K5GhKidAc?si=g6eadiywGIut_RAi\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" allowfullscreen\u003e\u003c\/iframe\u003e\n\u003c\/noscript\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Biosan","offers":[{"title":"Default Title","offer_id":57792241238351,"sku":"MSC-6000","price":650.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0946\/5105\/6463\/files\/msc_6000.png.1200x1200_q85.png?v=1779902619"},{"product_id":"biosan-msc-2p-mini-centrifuge","title":"Biosan MSC-2P Mini-Centrifuge vortex for PCR plates","description":"\u003ch3 data-section-id=\"1hpcofy\" data-start=\"0\" data-end=\"58\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"4\" data-end=\"58\"\u003eBiosan MSC-2P Minicentrifuge Vortex for PCR Plates\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"60\" data-end=\"388\"\u003eMinicentrifuge vortex designed for PCR sample preparation, reagent mixing, sample spin down, DNA analysis, and molecular biology workflows. Suitable for PCR laboratories, molecular biology laboratories, biotechnology laboratories, diagnostic laboratories, and research facilities working with PCR plates and microvolume samples.\u003c\/p\u003e\n\u003cp data-start=\"390\" data-end=\"781\"\u003eThe Biosan MSC-2P combines centrifugation and vortex mixing in a single device. The built in Spin-Mix-Spin (SMS) algorithm helps collect reagents at the bottom of PCR wells, mix samples, and re collect reagents to support consistent sample preparation before PCR analysis. The unit can process two PCR plates simultaneously and offers four operating modes for different laboratory workflows.\u003c\/p\u003e\n\u003ch4 data-start=\"783\" data-end=\"806\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"788\" data-end=\"806\"\u003eTechnical Data\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul data-start=\"808\" data-end=\"1078\"\u003e\n\u003cli data-section-id=\"1pdpoml\" data-start=\"808\" data-end=\"843\"\u003eSpeed range from 500 to 3,500 RPM\u003c\/li\u003e\n\u003cli data-section-id=\"12zr8lm\" data-start=\"844\" data-end=\"866\"\u003eMaximum RCF: 610 × g\u003c\/li\u003e\n\u003cli data-section-id=\"95xo9r\" data-start=\"867\" data-end=\"909\"\u003eSMS cycle regulation from 1 to 10 cycles\u003c\/li\u003e\n\u003cli data-section-id=\"sdran4\" data-start=\"910\" data-end=\"953\"\u003eCentrifugation timer from 0 to 10 minutes\u003c\/li\u003e\n\u003cli data-section-id=\"1konfco\" data-start=\"954\" data-end=\"988\"\u003eVortex timer from 0 to 5 minutes\u003c\/li\u003e\n\u003cli data-section-id=\"p6oqz7\" data-start=\"989\" data-end=\"1024\"\u003eSpeed setting resolution: 100 RPM\u003c\/li\u003e\n\u003cli data-section-id=\"9p0sex\" data-start=\"1025\" data-end=\"1038\"\u003eLCD display\u003c\/li\u003e\n\u003cli data-section-id=\"hrkbf9\" data-start=\"1039\" data-end=\"1078\"\u003eProcesses 2 PCR plates simultaneously\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"1080\" data-end=\"1101\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1085\" data-end=\"1101\"\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul data-start=\"1103\" data-end=\"1304\"\u003e\n\u003cli data-section-id=\"1ikm86u\" data-start=\"1103\" data-end=\"1127\"\u003ePCR sample preparation\u003c\/li\u003e\n\u003cli data-section-id=\"k7n4s1\" data-start=\"1128\" data-end=\"1142\"\u003eDNA analysis\u003c\/li\u003e\n\u003cli data-section-id=\"13xtere\" data-start=\"1143\" data-end=\"1159\"\u003eReagent mixing\u003c\/li\u003e\n\u003cli data-section-id=\"dbi3p4\" data-start=\"1160\" data-end=\"1178\"\u003eSample spin down\u003c\/li\u003e\n\u003cli data-section-id=\"1dli1jn\" data-start=\"1179\" data-end=\"1208\"\u003eMolecular biology workflows\u003c\/li\u003e\n\u003cli data-section-id=\"fqobz7\" data-start=\"1209\" data-end=\"1237\"\u003eBiotechnology applications\u003c\/li\u003e\n\u003cli data-section-id=\"9kok0q\" data-start=\"1238\" data-end=\"1269\"\u003eDiagnostic laboratory testing\u003c\/li\u003e\n\u003cli data-section-id=\"1fc6wrf\" data-start=\"1270\" data-end=\"1304\"\u003eResearch laboratory applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"1306\" data-end=\"1327\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1311\" data-end=\"1327\"\u003eKey Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul data-start=\"1329\" data-end=\"1727\"\u003e\n\u003cli data-section-id=\"mlpq2g\" data-start=\"1329\" data-end=\"1426\"\u003eCentrifuge, vortex mixer, combined centrifuge vortex mode, and SMS algorithm mode in one device\u003c\/li\u003e\n\u003cli data-section-id=\"27ipbr\" data-start=\"1427\" data-end=\"1458\"\u003eSpin-Mix-Spin (SMS) algorithm\u003c\/li\u003e\n\u003cli data-section-id=\"hrkbf9\" data-start=\"1459\" data-end=\"1498\"\u003eProcesses 2 PCR plates simultaneously\u003c\/li\u003e\n\u003cli data-section-id=\"rqnwgf\" data-start=\"1499\" data-end=\"1535\"\u003eCompatible with 96 well PCR plates\u003c\/li\u003e\n\u003cli data-section-id=\"1i3eyan\" data-start=\"1536\" data-end=\"1573\"\u003eCompatible with 384 well PCR plates\u003c\/li\u003e\n\u003cli data-section-id=\"14zv57v\" data-start=\"1574\" data-end=\"1630\"\u003eCompatible with PCR tube strips using optional adapter\u003c\/li\u003e\n\u003cli data-section-id=\"dy804d\" data-start=\"1631\" data-end=\"1678\"\u003eAdjustable centrifugation and vortex settings\u003c\/li\u003e\n\u003cli data-section-id=\"13vtv12\" data-start=\"1679\" data-end=\"1727\"\u003eDesigned for PCR and DNA analysis laboratories\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Biosan","offers":[{"title":"Default Title","offer_id":57792279904591,"sku":"MSC-2P","price":620.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0946\/5105\/6463\/files\/msc-2p.png.1200x1200_q85.png?v=1779902786"}],"url":"https:\/\/zentra-eu.com\/collections\/mini-centrifuges-vortex-mixers.oembed","provider":"Zentra ","version":"1.0","type":"link"}