{"title":"Dry Block Thermostat","description":"","products":[{"product_id":"biosan-bio-tdb-100-dry-block-thermostat","title":"Biosan Bio TDB-100 Dry Block Thermostat","description":"\u003ch3 data-section-id=\"12cr1mx\" data-start=\"0\" data-end=\"47\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"4\" data-end=\"47\"\u003eBiosan Bio TDB-100 Dry Block Thermostat\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"49\" data-end=\"316\"\u003eDry block thermostat designed for incubation of microtubes at controlled temperatures. Suitable for molecular biology laboratories, biotechnology laboratories, clinical laboratories, research laboratories, sample preparation workflows, and long incubation procedures.\u003c\/p\u003e\n\u003cp data-start=\"318\" data-end=\"606\"\u003eThe Biosan Bio TDB-100 provides temperature controlled incubation for the most commonly used laboratory microtubes. The built in aluminium block accommodates three different microtube sizes, while the digital display shows both set and actual temperature and time values during operation.\u003c\/p\u003e\n\u003ch4 data-start=\"608\" data-end=\"631\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"613\" data-end=\"631\"\u003eTechnical Data\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul data-start=\"633\" data-end=\"950\"\u003e\n\u003cli data-section-id=\"1isqzh2\" data-start=\"633\" data-end=\"681\"\u003eTemperature setting range from +25°C to +100°C\u003c\/li\u003e\n\u003cli data-section-id=\"64i9ci\" data-start=\"682\" data-end=\"743\"\u003eTemperature control range from +5°C above ambient to +100°C\u003c\/li\u003e\n\u003cli data-section-id=\"j4yz5r\" data-start=\"744\" data-end=\"784\"\u003eTemperature stability at +37°C: ±0.1°C\u003c\/li\u003e\n\u003cli data-section-id=\"d75blm\" data-start=\"785\" data-end=\"826\"\u003eTemperature uniformity at +37°C: ±0.1°C\u003c\/li\u003e\n\u003cli data-section-id=\"1itoi3e\" data-start=\"827\" data-end=\"866\"\u003eTemperature setting resolution: 0.1°C\u003c\/li\u003e\n\u003cli data-section-id=\"hkj6aj\" data-start=\"867\" data-end=\"908\"\u003eDigital timer from 1 minute to 96 hours\u003c\/li\u003e\n\u003cli data-section-id=\"6ydi9f\" data-start=\"909\" data-end=\"936\"\u003eContinuous operation mode\u003c\/li\u003e\n\u003cli data-section-id=\"9p0sex\" data-start=\"937\" data-end=\"950\"\u003eLCD display\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"952\" data-end=\"973\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"957\" data-end=\"973\"\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul data-start=\"975\" data-end=\"1170\"\u003e\n\u003cli data-section-id=\"2602ps\" data-start=\"975\" data-end=\"994\"\u003eSample incubation\u003c\/li\u003e\n\u003cli data-section-id=\"1dli1jn\" data-start=\"995\" data-end=\"1024\"\u003eMolecular biology workflows\u003c\/li\u003e\n\u003cli data-section-id=\"fqobz7\" data-start=\"1025\" data-end=\"1053\"\u003eBiotechnology applications\u003c\/li\u003e\n\u003cli data-section-id=\"igow1m\" data-start=\"1054\" data-end=\"1086\"\u003eClinical laboratory procedures\u003c\/li\u003e\n\u003cli data-section-id=\"1l0m60n\" data-start=\"1087\" data-end=\"1107\"\u003eSample preparation\u003c\/li\u003e\n\u003cli data-section-id=\"t2g835\" data-start=\"1108\" data-end=\"1135\"\u003eLong incubation processes\u003c\/li\u003e\n\u003cli data-section-id=\"1fc6wrf\" data-start=\"1136\" data-end=\"1170\"\u003eResearch laboratory applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"1172\" data-end=\"1193\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1177\" data-end=\"1193\"\u003eKey Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul data-start=\"1195\" data-end=\"1519\"\u003e\n\u003cli data-section-id=\"1vynvup\" data-start=\"1195\" data-end=\"1232\"\u003eDry block thermostat for microtubes\u003c\/li\u003e\n\u003cli data-section-id=\"17cdxfy\" data-start=\"1233\" data-end=\"1269\"\u003eBuilt in universal aluminium block\u003c\/li\u003e\n\u003cli data-section-id=\"1hzaf61\" data-start=\"1270\" data-end=\"1322\"\u003eSimultaneous display of set and actual temperature\u003c\/li\u003e\n\u003cli data-section-id=\"1wpogi8\" data-start=\"1323\" data-end=\"1368\"\u003eSimultaneous display of set and actual time\u003c\/li\u003e\n\u003cli data-section-id=\"60vcgv\" data-start=\"1369\" data-end=\"1421\"\u003eSupports 0.2 ml, 0.5 ml, and 1.5\/2.0 ml microtubes\u003c\/li\u003e\n\u003cli data-section-id=\"dquuc4\" data-start=\"1422\" data-end=\"1456\"\u003eTemperature control up to +100°C\u003c\/li\u003e\n\u003cli data-section-id=\"1u5gu2s\" data-start=\"1457\" data-end=\"1484\"\u003eDigital timer and display\u003c\/li\u003e\n\u003cli data-section-id=\"y97tbg\" data-start=\"1485\" data-end=\"1519\"\u003eTemperature calibration function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cnoscript class=\"loading-lazy\"\u003e\n  \u003ciframe loading=\"lazy\" width=\"560\" height=\"315\" style=\"width: 100%; max-width: 100%; height: auto; aspect-ratio: 16\/9;\" src=\"https:\/\/www.youtube.com\/embed\/4PdX5w4u-08?si=T39Dgpy1b9UDH6TL\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" allowfullscreen\u003e\u003c\/iframe\u003e\n\u003c\/noscript\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Biosan","offers":[{"title":"Default Title","offer_id":57792414089551,"sku":"TDB-100","price":685.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0946\/5105\/6463\/files\/bio_tdb_100.png.1200x1200_q85.png?v=1779904639"},{"product_id":"biosan-tdb-120-dry-block-thermostat","title":"Biosan TDB-120 Dry Block Thermostat","description":"\u003ch3 data-section-id=\"r86brj\" data-start=\"0\" data-end=\"43\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"4\" data-end=\"43\"\u003eBiosan TDB-120 Dry Block Thermostat\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"45\" data-end=\"338\"\u003eDry block thermostat designed for controlled incubation of samples in laboratory tubes. Suitable for PCR analysis, molecular biology laboratories, biotechnology laboratories, clinical laboratories, research laboratories, and sample preparation workflows requiring accurate temperature control.\u003c\/p\u003e\n\u003cp data-start=\"340\" data-end=\"718\"\u003eThe Biosan TDB-120 is designed to maintain stable temperatures for samples placed in aluminium block sockets. The system provides precise temperature control and uniform heat distribution across the block, making it suitable for routine laboratory procedures and PCR related applications. Set and actual temperature and time values are displayed simultaneously during operation.\u003c\/p\u003e\n\u003ch4 data-start=\"720\" data-end=\"743\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"725\" data-end=\"743\"\u003eTechnical Data\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul data-start=\"745\" data-end=\"1062\"\u003e\n\u003cli data-section-id=\"1isscic\" data-start=\"745\" data-end=\"793\"\u003eTemperature setting range from +25°C to +120°C\u003c\/li\u003e\n\u003cli data-section-id=\"64jz80\" data-start=\"794\" data-end=\"855\"\u003eTemperature control range from +5°C above ambient to +120°C\u003c\/li\u003e\n\u003cli data-section-id=\"j4yz5r\" data-start=\"856\" data-end=\"896\"\u003eTemperature stability at +37°C: ±0.1°C\u003c\/li\u003e\n\u003cli data-section-id=\"d75blm\" data-start=\"897\" data-end=\"938\"\u003eTemperature uniformity at +37°C: ±0.1°C\u003c\/li\u003e\n\u003cli data-section-id=\"1itoi3e\" data-start=\"939\" data-end=\"978\"\u003eTemperature setting resolution: 0.1°C\u003c\/li\u003e\n\u003cli data-section-id=\"hkj6aj\" data-start=\"979\" data-end=\"1020\"\u003eDigital timer from 1 minute to 96 hours\u003c\/li\u003e\n\u003cli data-section-id=\"6ydi9f\" data-start=\"1021\" data-end=\"1048\"\u003eContinuous operation mode\u003c\/li\u003e\n\u003cli data-section-id=\"9p0sex\" data-start=\"1049\" data-end=\"1062\"\u003eLCD display\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"1064\" data-end=\"1085\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1069\" data-end=\"1085\"\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul data-start=\"1087\" data-end=\"1269\"\u003e\n\u003cli data-section-id=\"1yzp09n\" data-start=\"1087\" data-end=\"1101\"\u003ePCR analysis\u003c\/li\u003e\n\u003cli data-section-id=\"2602ps\" data-start=\"1102\" data-end=\"1121\"\u003eSample incubation\u003c\/li\u003e\n\u003cli data-section-id=\"1dli1jn\" data-start=\"1122\" data-end=\"1151\"\u003eMolecular biology workflows\u003c\/li\u003e\n\u003cli data-section-id=\"fqobz7\" data-start=\"1152\" data-end=\"1180\"\u003eBiotechnology applications\u003c\/li\u003e\n\u003cli data-section-id=\"igow1m\" data-start=\"1181\" data-end=\"1213\"\u003eClinical laboratory procedures\u003c\/li\u003e\n\u003cli data-section-id=\"1l0m60n\" data-start=\"1214\" data-end=\"1234\"\u003eSample preparation\u003c\/li\u003e\n\u003cli data-section-id=\"1fc6wrf\" data-start=\"1235\" data-end=\"1269\"\u003eResearch laboratory applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"1271\" data-end=\"1292\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1276\" data-end=\"1292\"\u003eKey Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul data-start=\"1294\" data-end=\"1653\"\u003e\n\u003cli data-section-id=\"10en1dk\" data-start=\"1294\" data-end=\"1337\"\u003eDry block thermostat for laboratory tubes\u003c\/li\u003e\n\u003cli data-section-id=\"dqthhy\" data-start=\"1338\" data-end=\"1372\"\u003eTemperature control up to +120°C\u003c\/li\u003e\n\u003cli data-section-id=\"r30r6t\" data-start=\"1373\" data-end=\"1419\"\u003eHigh temperature uniformity across the block\u003c\/li\u003e\n\u003cli data-section-id=\"d8yn0v\" data-start=\"1420\" data-end=\"1448\"\u003eHigh temperature stability\u003c\/li\u003e\n\u003cli data-section-id=\"17omq0s\" data-start=\"1449\" data-end=\"1497\"\u003eMicroprocessor controlled temperature and time\u003c\/li\u003e\n\u003cli data-section-id=\"1hzaf61\" data-start=\"1498\" data-end=\"1550\"\u003eSimultaneous display of set and actual temperature\u003c\/li\u003e\n\u003cli data-section-id=\"1wpogi8\" data-start=\"1551\" data-end=\"1596\"\u003eSimultaneous display of set and actual time\u003c\/li\u003e\n\u003cli data-section-id=\"2hbu65\" data-start=\"1597\" data-end=\"1653\"\u003eAvailable with different built in block configurations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cnoscript class=\"loading-lazy\"\u003e\n  \u003ciframe loading=\"lazy\" width=\"560\" height=\"315\" style=\"width: 100%; max-width: 100%; height: auto; aspect-ratio: 16\/9;\" src=\"https:\/\/www.youtube.com\/embed\/DH-AoWPtKPs?si=aJYuB8zb6a1Xz_fR\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" allowfullscreen\u003e\u003c\/iframe\u003e\n\u003c\/noscript\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Biosan","offers":[{"title":"Default Title","offer_id":57792426410319,"sku":"TDB-120","price":690.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0946\/5105\/6463\/files\/tdb_120_front.png.1200x1200_q85.png?v=1779904863"},{"product_id":"biosan-ch-100-heating-and-cooling-dry-block-thermostat","title":"Biosan CH-100 Heating and Cooling Dry Block Thermostat","description":"\u003ch3 data-section-id=\"1vnj4zs\" data-start=\"0\" data-end=\"62\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"4\" data-end=\"62\"\u003eBiosan CH-100 Heating and Cooling Dry Block Thermostat\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"64\" data-end=\"395\"\u003eHeating and cooling dry block thermostat designed for sample preparation, enzyme reactions, hybridization reactions, DNA analysis, and temperature controlled incubation of microtubes. Suitable for molecular biology laboratories, biotechnology laboratories, clinical laboratories, research laboratories, and diagnostic laboratories.\u003c\/p\u003e\n\u003cp data-start=\"397\" data-end=\"702\"\u003eThe Biosan CH-100 combines heating and cooling functions in a single device. The aluminium block and Peltier cooling system allow rapid switching between cooling and heating modes, making the unit suitable for laboratory procedures that require precise temperature control across a wide temperature range.\u003c\/p\u003e\n\u003ch4 data-start=\"704\" data-end=\"727\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"709\" data-end=\"727\"\u003eTechnical Data\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul data-start=\"729\" data-end=\"1038\"\u003e\n\u003cli data-section-id=\"1auh0hi\" data-start=\"729\" data-end=\"777\"\u003eTemperature setting range from -10°C to +100°C\u003c\/li\u003e\n\u003cli data-section-id=\"u52o03\" data-start=\"778\" data-end=\"839\"\u003eTemperature control range from 30°C below ambient to +100°C\u003c\/li\u003e\n\u003cli data-section-id=\"1noovme\" data-start=\"840\" data-end=\"871\"\u003eTemperature stability: ±0.1°C\u003c\/li\u003e\n\u003cli data-section-id=\"9d6r2k\" data-start=\"872\" data-end=\"914\"\u003eTemperature uniformity at +37°C: ±0.25°C\u003c\/li\u003e\n\u003cli data-section-id=\"1itoi3e\" data-start=\"915\" data-end=\"954\"\u003eTemperature setting resolution: 0.1°C\u003c\/li\u003e\n\u003cli data-section-id=\"hkj6aj\" data-start=\"955\" data-end=\"996\"\u003eDigital timer from 1 minute to 96 hours\u003c\/li\u003e\n\u003cli data-section-id=\"6ydi9f\" data-start=\"997\" data-end=\"1024\"\u003eContinuous operation mode\u003c\/li\u003e\n\u003cli data-section-id=\"9p0sex\" data-start=\"1025\" data-end=\"1038\"\u003eLCD display\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"1040\" data-end=\"1061\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1045\" data-end=\"1061\"\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul data-start=\"1063\" data-end=\"1270\"\u003e\n\u003cli data-section-id=\"1l0m60n\" data-start=\"1063\" data-end=\"1083\"\u003eSample preparation\u003c\/li\u003e\n\u003cli data-section-id=\"13xs182\" data-start=\"1084\" data-end=\"1102\"\u003eEnzyme reactions\u003c\/li\u003e\n\u003cli data-section-id=\"14ll1w0\" data-start=\"1103\" data-end=\"1128\"\u003eHybridization reactions\u003c\/li\u003e\n\u003cli data-section-id=\"k7n4s1\" data-start=\"1129\" data-end=\"1143\"\u003eDNA analysis\u003c\/li\u003e\n\u003cli data-section-id=\"1dli1jn\" data-start=\"1144\" data-end=\"1173\"\u003eMolecular biology workflows\u003c\/li\u003e\n\u003cli data-section-id=\"fqobz7\" data-start=\"1174\" data-end=\"1202\"\u003eBiotechnology applications\u003c\/li\u003e\n\u003cli data-section-id=\"igow1m\" data-start=\"1203\" data-end=\"1235\"\u003eClinical laboratory procedures\u003c\/li\u003e\n\u003cli data-section-id=\"1fc6wrf\" data-start=\"1236\" data-end=\"1270\"\u003eResearch laboratory applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"1272\" data-end=\"1293\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1277\" data-end=\"1293\"\u003eKey Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul data-start=\"1295\" data-end=\"1660\"\u003e\n\u003cli data-section-id=\"1sqmzkf\" data-start=\"1295\" data-end=\"1330\"\u003eHeating and cooling in one device\u003c\/li\u003e\n\u003cli data-section-id=\"1rc8w2g\" data-start=\"1331\" data-end=\"1373\"\u003eTemperature control from -10°C to +100°C\u003c\/li\u003e\n\u003cli data-section-id=\"1yu0y2k\" data-start=\"1374\" data-end=\"1424\"\u003eFast switching between cooling and heating modes\u003c\/li\u003e\n\u003cli data-section-id=\"crmsyo\" data-start=\"1425\" data-end=\"1455\"\u003ePeltier based cooling system\u003c\/li\u003e\n\u003cli data-section-id=\"17omq0s\" data-start=\"1456\" data-end=\"1504\"\u003eMicroprocessor controlled temperature and time\u003c\/li\u003e\n\u003cli data-section-id=\"1hzaf61\" data-start=\"1505\" data-end=\"1557\"\u003eSimultaneous display of set and actual temperature\u003c\/li\u003e\n\u003cli data-section-id=\"1wpogi8\" data-start=\"1558\" data-end=\"1603\"\u003eSimultaneous display of set and actual time\u003c\/li\u003e\n\u003cli data-section-id=\"2hbu65\" data-start=\"1604\" data-end=\"1660\"\u003eAvailable with different built in block configurations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cnoscript class=\"loading-lazy\"\u003e\n  \u003ciframe loading=\"lazy\" width=\"560\" height=\"315\" style=\"width: 100%; max-width: 100%; height: auto; aspect-ratio: 16\/9;\" src=\"https:\/\/www.youtube.com\/embed\/95me8NJaQH8?si=rh472j9pJgw6yk2z\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" allowfullscreen\u003e\u003c\/iframe\u003e\n\u003c\/noscript\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Biosan","offers":[{"title":"Default Title","offer_id":57792527991119,"sku":"CH-100","price":1100.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0946\/5105\/6463\/files\/ch_100_YhlAwE8.png.1200x1200_q85.png?v=1779906397"},{"product_id":"biosan-ch-3-150-dry-block-thermostat","title":"Biosan CH-3-150 Dry Block Thermostat","description":"\u003cdiv class=\"qMYqUG_convSearchResultHighlightRoot\"\u003e\n\u003cdiv data-is-intersecting=\"true\" data-turn-id-container=\"request-6a21a336-cba8-83eb-9860-0f228ecd9a02-22\" class=\"\"\u003e\n\u003csection data-turn=\"assistant\" data-scroll-anchor=\"false\" data-testid=\"conversation-turn-126\" data-turn-id-container=\"request-6a21a336-cba8-83eb-9860-0f228ecd9a02-22\" data-turn-id=\"request-6a21a336-cba8-83eb-9860-0f228ecd9a02-22\" dir=\"auto\" class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\" data-conversation-screenshot-content=\"\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-message-model-slug=\"gpt-5-5\" dir=\"auto\" data-turn-start-message=\"true\" data-message-id=\"6af117c8-b929-404e-811f-265c84ef97fa\" data-message-author-role=\"assistant\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full dark markdown-new-styling\"\u003e\n\u003ch3 data-end=\"67\" data-start=\"0\" data-section-id=\"1hjo0cr\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"67\" data-start=\"4\"\u003eBiosan CH 3-150 Combitherm-2 Heating and Cooling Thermostat\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-end=\"395\" data-start=\"69\"\u003eHeating and cooling thermostat designed for sample thermostabilisation, enzyme reactions, hybridization reactions, DNA analysis, and temperature controlled laboratory procedures. Suitable for molecular biology laboratories, biotechnology laboratories, clinical laboratories, research laboratories, and diagnostic laboratories.\u003c\/p\u003e\n\u003cp data-end=\"801\" data-start=\"397\"\u003eThe Biosan CH 3-150 Combitherm-2 combines independent heating and cooling thermoblocks in a single unit. Each section can be controlled separately and programmed independently, allowing simultaneous heating and cooling of different samples. The system supports up to 16 user programs for each section and is designed for applications requiring precise temperature control across a wide temperature range.\u003c\/p\u003e\n\u003ch4 data-end=\"826\" data-start=\"803\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"826\" data-start=\"808\"\u003eTechnical Data\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul data-end=\"1164\" data-start=\"828\"\u003e\n\u003cli data-end=\"876\" data-start=\"828\" data-section-id=\"1o0j8n1\"\u003eHeating temperature range from +25°C to +150°C\u003c\/li\u003e\n\u003cli data-end=\"923\" data-start=\"877\" data-section-id=\"1gis7ji\"\u003eCooling temperature range from -3°C to +20°C\u003c\/li\u003e\n\u003cli data-end=\"963\" data-start=\"924\" data-section-id=\"s1v226\"\u003eHeating temperature stability: ±0.1°C\u003c\/li\u003e\n\u003cli data-end=\"1003\" data-start=\"964\" data-section-id=\"1k6dhdl\"\u003eCooling temperature stability: ±0.1°C\u003c\/li\u003e\n\u003cli data-end=\"1051\" data-start=\"1004\" data-section-id=\"hozsmt\"\u003eCooling temperature setting resolution: 0.1°C\u003c\/li\u003e\n\u003cli data-end=\"1104\" data-start=\"1052\" data-section-id=\"1mnbkx1\"\u003eDigital timer from 1 minute to 99 hours 59 minutes\u003c\/li\u003e\n\u003cli data-end=\"1118\" data-start=\"1105\" data-section-id=\"9p0sex\"\u003eLCD display\u003c\/li\u003e\n\u003cli data-end=\"1164\" data-start=\"1119\" data-section-id=\"js3j1w\"\u003e16 heating programs and 16 cooling programs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-end=\"1187\" data-start=\"1166\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"1187\" data-start=\"1171\"\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul data-end=\"1404\" data-start=\"1189\"\u003e\n\u003cli data-end=\"1217\" data-start=\"1189\" data-section-id=\"bn1zvl\"\u003eSample thermostabilisation\u003c\/li\u003e\n\u003cli data-end=\"1236\" data-start=\"1218\" data-section-id=\"13xs182\"\u003eEnzyme reactions\u003c\/li\u003e\n\u003cli data-end=\"1262\" data-start=\"1237\" data-section-id=\"14ll1w0\"\u003eHybridization reactions\u003c\/li\u003e\n\u003cli data-end=\"1277\" data-start=\"1263\" data-section-id=\"k7n4s1\"\u003eDNA analysis\u003c\/li\u003e\n\u003cli data-end=\"1307\" data-start=\"1278\" data-section-id=\"1dli1jn\"\u003eMolecular biology workflows\u003c\/li\u003e\n\u003cli data-end=\"1336\" data-start=\"1308\" data-section-id=\"fqobz7\"\u003eBiotechnology applications\u003c\/li\u003e\n\u003cli data-end=\"1369\" data-start=\"1337\" data-section-id=\"igow1m\"\u003eClinical laboratory procedures\u003c\/li\u003e\n\u003cli data-end=\"1404\" data-start=\"1370\" data-section-id=\"1fc6wrf\"\u003eResearch laboratory applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-end=\"1427\" data-start=\"1406\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"1427\" data-start=\"1411\"\u003eKey Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul data-end=\"1780\" data-start=\"1429\"\u003e\n\u003cli data-end=\"1471\" data-start=\"1429\" data-section-id=\"92mg88\"\u003eIndependent heating and cooling sections\u003c\/li\u003e\n\u003cli data-end=\"1527\" data-start=\"1472\" data-section-id=\"e6c910\"\u003eSimultaneous heating and cooling of different samples\u003c\/li\u003e\n\u003cli data-end=\"1550\" data-start=\"1528\" data-section-id=\"55v9c2\"\u003eHeating up to +150°C\u003c\/li\u003e\n\u003cli data-end=\"1573\" data-start=\"1551\" data-section-id=\"1j0477\"\u003eCooling down to -3°C\u003c\/li\u003e\n\u003cli data-end=\"1623\" data-start=\"1574\" data-section-id=\"j6s70d\"\u003eUser programmable temperature and time settings\u003c\/li\u003e\n\u003cli data-end=\"1658\" data-start=\"1624\" data-section-id=\"1w9t6qk\"\u003e16 programmable heating profiles\u003c\/li\u003e\n\u003cli data-end=\"1693\" data-start=\"1659\" data-section-id=\"1wuro2z\"\u003e16 programmable cooling profiles\u003c\/li\u003e\n\u003cli data-end=\"1749\" data-start=\"1694\" data-section-id=\"160d5gn\"\u003eCompatible with multiple interchangeable thermoblocks\u003c\/li\u003e\n\u003cli data-end=\"1780\" data-start=\"1750\" data-section-id=\"crmsyo\"\u003ePeltier based cooling system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cnoscript class=\"loading-lazy\"\u003e\n  \u003ciframe loading=\"lazy\" width=\"560\" height=\"315\" style=\"width: 100%; max-width: 100%; height: auto; aspect-ratio: 16\/9;\" src=\"https:\/\/www.youtube.com\/embed\/d8uLlRsbxQk?si=sXJfWCXn-R0QOwjt\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" allowfullscreen=\"\"\u003e\u003c\/iframe\u003e\n\u003c\/noscript\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Biosan","offers":[{"title":"Default Title","offer_id":57794795569487,"sku":"CH-3-150","price":1400.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0946\/5105\/6463\/files\/ch_3_150.png.1200x1200_q85.png?v=1779946498"}],"url":"https:\/\/zentra-eu.com\/collections\/dry-block-thermostat.oembed","provider":"Zentra ","version":"1.0","type":"link"}